Zone de Texte: AgmedaWin – gap filling and plausibility checking Zone de Texte: gap filling
 small gaps (up to 3 hours) are filled via linear interpolation
 big gaps (more than 3 hours) are filled with data of an adjacent station,
	 merging the data exactly into the gap


plausibility checking

internal plausibility checking:

internal plausibility checking is done for the data of a single station using several
checking algorithms:

checking of lower and upper limits
several algorithms for checking the dynamic of the data,
	e.g.	12 equal values of air temperature in series
		12 equal values of precipitation in series bigger than 0
comparing a value with its previous and following value to detect „big jumps“

Values which are not plausible are marked with the plausibility sign „*“.

external plausibility checking:

external plausibility checking is done to compare data of adjacent stations. Zone de Texte: Zone de Texte: Central Institution for Decision Support Systems in Crop Protection Zone de Texte: Keil, Kleinhenz